TROUBLESHOOTING (cont.)
PROBLEM PROBABLE CAUSE REMEDY
Water does not heat to proper tem-
perature (cont.)
IMPORTANT: Make sure no tem-
perature tests are taken before the
ready light is "ON". Tank tempera-
ture must be stabilized before read-
ings are taken.
6. Tank Heater
7. Fuse Holder & Fuse (MV models
only)
8. Thermal Fuse (MV models only)
Disconnect the brewer from the
power source. Check for continuity
between the white terminal of the
terminal block (or red terminal on
208/240volt models) and the black
wire on the relay on the control
board (Toggle Switch must be in
120/208-240V position on 208V &
240V models). There should be a
low OHM reading. If no continuity is
present, check for a wiring prob-
lem, then replace the tank heater if
no wiring problem is found. (See
page 26)
Check fuse and replace if neces-
sary. (See page 31)
Check thermal fuse for continuity
and replace if necessary. (See page
32)