Bunn CDBCF APS-MV Coffeemaker User Manual


 
Page 32
C
A
U
T
IO
N
:
W
ARMERS AND
SU
RFACES ARE HOT
TRM
2
J1
J2
J3
J4
J5
J6
J7
TR
M
1
SERVICE (cont.)
FIG. 15 FUSE HOLDER AND FUSE ASSEMBLY
Location:
The fuse holder and fuse assembly is located on
the left rear side of the brewer.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Remove the cap from the fuse holder and remove
the fuse.
3. With an ohmmeter, check for continuity through
the fuse.
If continuity is present as described, reinstall the fuse,
the fuse is operating properly.
If continuity is not present as described, replace the
fuse.
P1937
FUSE HOLDER/FUSE ASSEMBLY MV models only
Removal and Replacement:
1. Remove the cap from the holder.
2. Remove fuse from the fuse holder and discard.
3. Install new 20 amp fuse in the holder.
4. Reinstall fuse holder cap.
29707 112801