Page 9
TROUBLESHOOTING (cont.)
Brew cycle will not start (cont.)
Water is not hot
PROBABLE CAUSE
REMEDY
3. ON/OFF Switch
4. Start Switch
5. Timer
6. Solenoid Valve
7. Water strainer/flow control
(.222 GPM)
1. Tank Heater Switch
2. (A) Limit Thermostat
(B) Thermal Cut-Off (Brewers
with Faucet)
CAUTION - Do not eliminate or
bypass limit thermostat or
thermal cut-off. Use only BOM
replacement part.
Limit Thermostat #29329.1000
Thermal Cut-Off #20211.0100
3. Control Thermostat
4. Tank Heater
Refer to
Service
- ON/OFF
Switch for testing. See page 17
Refer to
Service
- Start Switch
for testing procedures. See page
19
Refer to
Service
- Timer for
testing procedures. See page 25
or 27
Refer to
Service
- Solenoid Valve
for testing procedures. See page
18
(A) Direction of flow arrow must
be pointing towards brewer.
(B) Remove the strainer/flow
control and check for obstruc-
tions. Clear or replace.
Refer to
Service
- Tank Heater
Switch for testing procedures.
See page 22
Refer to
Service
- Limit Thermo-
stat for testing procedures. See
page 16. Thermal Cut-Off for
testing procedures. See page 24
Refer to
Service
- Control Ther-
mostat for testing procedures.
See page 14
Refer to
Service
- Tank Heater
for testing procedures. See page
20
10478 061500
PROBLEM