Page 12
TROUBLESHOOTING (cont.)
Water overflows filter (cont.)
Beverage overflows server.
Weak beverage
2. Type of paper filters
3. No sprayhead
1. Beverage left in server
2. Volume adjustment needed
3. Dispense valve
1. Type of paper filters
2. Coffee
3. Sprayhead
4. Funnel loading
5. Water temperature
BUNN
®
paper filters should be used
for proper extraction.
Check sprayhead
The brew cycle should be started
only with an empty server under the
funnel.
Refer to Setting or Adjusting Batch
Volumes, page 7
Refer to
Service
- Dispense valve for
testing procedures. See page 20
BUNN
®
paper filters should be used
for proper extraction.
A sufficient quantity of fresh drip or
regular grind should be used for
proper extraction.
B.O.M. Sprayhead #01082.0002
should be used to properly wet the
bed of ground coffee in the funnel.
The BUNN
®
paper filter should be
centered in the funnel and the bed of
ground coffee leveled by gentle shak-
ing.
Empty the server, remove its cover.
Place empty funnel over the server
entrance, with ON/OFF switch in the
"ON" position press the start switch
and release it. Check the water tem-
perature immediately below the
sprayhead with a thermometer. The
reading should not be less than 195°
F.
Problem Probable Cause Remedy
32248 100500