Page 7
32248 100500
Setting or adjusting the brewer’s controls
Refer to the function list for the accessible screen numbers and their values. Scroll to the desired function
screen and change the value by pressing either the “+” or “–“ keys.
The change will not be entered into the programming until you move to another screen by scrolling either
up-or-down with the “FUNC” key.
Setting or adjusting the tank’s water temperature
At the home screen, the actual temperature of the water in the tank is displayed. The target tank temperature
is set at the FUNC 101 screen which is in the "SECURED" Section.
Setting or adjusting the batch volumes
Refer to the function list to determine the proper screen for batch size and side (left or right) of the brewer
being set. Program the total amount of brew water as well as the desired percentage of bypass
Note: If the programmed value doesn’t produce the exact volume desired, simply adjust it by pressing either
the “+” or “–“ keys as required to increase-or-decrease it by the difference in ounces.
Setting or adjusting parameters for pulsed brewing
The brewer is capable of pulsing the sprayhead and bypass flows on-and-off over the course of the brew
cycle. This gives you the ability to fine-tune the brewer for specific flavor profiles. Refer to the function list for
the appropriate screen numbers and their values. Pulse brewing can be programmed for any and all batch sizes.
Three settings must be made or changed for each:
a) The duration in seconds of Off time that occurs between the initial On and subsequent On times.
b) The initial On time in seconds for the sufficient grounds wetting.
c) The duration in seconds of subsequent On times that will occur for the remainder of the brew cycle.
Setting or adjusting passwords
The DBC has two passwords that can be set (to any number up to 4 digits) to prevent unauthorized access
to programming section of the list. Passwords are default set to “0” which allows free access. FUNC 14 screen is
used to set password for the "USER" Section and FUNC XXX (see Function List) for the "SECURED" Section. If the
password is forgotten after being set, there is no way of recovering it. The controller must have the factory
settings restored by simultaneously pressing and holding the “+” and “-” keys while powering-up the brewer.
Hold both keys until the display begins to count, then release them.