13
17. Install grind selector dial plate (18) with adjust-
ing screw w/bearing (19) onto the grind cham-
ber and secure with two .250"-20 screws (1).
18. Install grind selector knob (17) onto the grind
selector dial plate (18).
NOTE: Refer to
ADJUSTMENTS
and reset the burrs.
SERVICE (cont.)
DC MOTOR AND GRIND CHAMBER - G1MD ONLY