Bunn LCA-2 LP Coffeemaker User Manual


 
16
PRIMING THE CONCENTRATE LINES
1. Open the dispenser door.
2. Select Prime on the Function Selector Switch and Run on the Mode Selector Switch.
3. Close the dispenser door.
4. Place a container under the dispense tip.
5. Activate the appropriate dispenser until concentrate flows from the dispense nozzle. Priming may take 5 to
10 seconds.
6. Open the dispenser door, select Normal on the Function Selector Switch.
Note: Concentrate may continue to drip out of dispense tip. The user may wish to Rinse (refer to Rinsing) the
dispenser to clean out the remaining concentrate.
DRAINING THE HOT WATER TANK
CAUTION: The dispenser must be disconnected from the power source throughout these steps.
1. Disconnect the dispenser from the power source.
2. Shut off and disconnect the incoming water supply.
3. Remove the right side access panel.
4. Pull out drain tube to empty into a sink or a container with a minimum of 200 ounce capacity.
5. Make sure drain clamp is closed, then remove drain plug.
6. Direct tube into sink or container and open drain clamp. Continue draining tank until ALL of the water is out.
Be careful when draining the water as it may be very hot.
7. Close drain clamp, insert drain plug, place drain tube back into machine, and replace the right side access
panel.
Note: The dispenser must be refilled using the Initial Fill & Heat steps before reconnecting the power source.
2
6
2
38791 031606