Page 11
40410 092407
PROGRAMMING - SMART WAVE WITH DISPLAY
BREW VOLUME SET-UP:
NOTE: Maximum water on time is 5 minutes.
1. Press the "HIDDEN" switch until display reads A1. This represents the adjust mode "Brew Time" for the "A"
brew switch. The display will then change to (minutes-seconds). Press "BREW A" to decrease time (-) or
"BREW B" to increase time (+).
2. Press and release "HIDDEN" switch until display reads A2. This represents the adjust mode "Brew Meter"
(Pulse Brew) for the "A" brew switch. The display will then change to (1-14). Brewer has 14 preset pulse brew
routines to choose from. Factory default is 1. With 14 being the maximum time. Press "BREW A" to decrease
(-) or "BREW B" to increase (+).
3. Press and release "HIDDEN" switch until display reads A3. This represents the adjust mode "Drip Out Time"
for the "A" brew switch. The display will then change to (minutes-seconds). Press "BREW A" to decrease time
(-) or "BREW B" to increase time (+).
4. Repeat steps 1 -3 for setting the "B" brew switch.
A1 = Brew switch "A" Brew time
A2 = Brew switch "A" Brew meter
A3 = Brew switch "A" Drip out time
B1 = Brew switch "B" Brew time
B2 = Brew switch "B" Brew meter
B3 = Brew switch "B" Drip out time
Restore Factory Defaults:
Press the "ENABLE BREW ON/OFF" switch while applying AC power. Continue pressing the "ENABLE BREW ON/
OFF" switch for 10 seconds. During that 10 seconds the middle bars on the display will be on. After 10 Seconds
the the 3 upper, middle and lower bars on the display will be lit for 5 seconds. During that 5 seconds, release and
again press the "ENABLE BREW ON/OFF" switch to restore default settings – the display will show “DONE”.
Note: The Restore process cannot be done when Dip Switch # 1 is On (Program Lockout)