Page 8
OPERATING CONTROLS - SILVER SERIES
(A) ENABLE BREW ON/OFF SWITCH
Pressing the "ENABLE BREW ON/OFF" switch (indicator on) enables the brew circuit, and energizes the tank refill
circuit. Pressing the switch again (indicator off) stops tank refilling and brewing. Stopping a brew cycle after
it has been started will not stop the flow of water into the server until the funnel is empty.
NOTE 1: – Stopping a brew cycle by pressing the "ENABLE BREW ON/OFF" switch to the "OFF" position, will dis-
able the tank refill circuit. If the level is low enough, tank heating may be disabled as well. Simply pressing the
"ENABLE BREW ON/OFF" switch to the "ON" position will allow the tank to replenish. Allow a few minutes for the
tank to heat back up to it's ready temperature.
NOTE 2: – Hot water will be available at the faucet in a limited amount when the "ENABLE BREW ON/OFF" switch
is in the "OFF" position because the tank will not refill. Refer to NOTE 1 regarding low level.
(B) SMALL BREW SWITCH
Momentarily pressing and releasing the switch starts the selected "SMALL" brew cycle when the "ENABLE BREW
ON/OFF" indicator is on. (Factory set for approx. 64 ounces)
(C) LARGE BREW SWITCH
Momentarily pressing and releasing the switch starts the selected "LARGE" brew cycle when the "ENABLE BREW
ON/OFF" indicator is on. (Factory set for approx. 64 ounces)
(D) STATUS INDICATOR
Steady green - ready to brew.
Steady red - tank is heating up.
Flashing red - brew cycle in process.
B C
A D
FIG 7
Smart Wave Silver Series
40410 092407
TM