Page 30
PROGRAMMING THE BREWER (cont.)
BYPASS OZ/M (SINGLE BREWERS)
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle.
This is NOT used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute.
Procedure to adjust the flow rate setting:
1. Press and hold the upper right hidden switch until
the display reads UNITS. Release the switch, then
press and release switch until the display reads
BYPAS OZ/M. The number represents what the
brewer thinks is the flow rate of the bypass valve
in ounces per minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display,
use the (-) and (+) to enter the correct flow rate
in ounces per minute.
3. When finished, press and release DONE. This saves
the new setting and advances to the next function
screen, CALIBRATE FLOW. Another alternative is to
press the ON/OFF switch located on the front switch
panel to exit the BYPASS OZ/M function and return to
the MAIN SCREEN.
BYPASS OZ/M (DUAL BREWERS)
This function allows the operator to view or to enter
the actual flow rate coming out of the bypass nozzle.
This is NOT used to change the actual flow rate, but to
tell the internal controller how fast the water is flowing.
The unit of measure is ounces per minute.
Procedure to adjust the flow rate setting:
1. Press and hold upper right hidden switch until
display reads UNITS. Release switch. Continue
to press and release switch until display reads L
BYPASS OZ/M. The number represents what the
brewer thinks is the flow rate of the bypass valve
in ounces per minute.
2. If the actual flow rate of the bypass valve is known,
but is different than the number on the display,
use the (-) and (+) to enter the correct flow rate
in ounces per minute.
3. When finished, press and release the DONE. This
saves the new setting and advances to R BYPS
OZ/M. When finished setting right side, press and
release DONE to advance to next function screen,
CALIBRATE FLOW. Another alternative is to press
and release either ON/OFF switch located on the
front switch panel to exit the BYPASS OZ/M func-
tion and return to the MAIN SCREEN.
R BYPS OZ/M: XX.X
(-) DONE (+)
L BYPS OZ/M: XX.X
(-) DONE (+)
CALIBRATE FLOW?
NO YES
BYPS OZ/M: XX.X
(-) DONE (+)
CALIBRATE FLOW?
NO YES
41342 080108