c) Minimum regulation of the hob burners:
turn the tap to minimum;
remove the knob and adjust the regulation screw, which is positioned in or next to the tap pin, until the
flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.
check that the flame does not turn off when you turn the tap quickly from high to low.
d) Regulating the primary air of the burners:
The primary air of the burners requires no regulation.
Adapting to different types of gas (main and top oven)
In order to adapt the oven to a different type of gas with respect to the gas for which it was manufactured
(indicated on the label), follow these simple steps:
a) Replacing the oven burner nozzle
open the oven door fully
pull out the sliding oven bottom
V
V
Z
Pry the fixing tab “V” and remove the oven burner
Unscrew the oven burner nozzle using the socket spanner for the nozzles “Z”, or a 7 mm socket spanner,
and replace it with a nozzle suited to the new type of gas (see Table 1).
Take particular care handling the spark plug wires and the thermocouple pipes.
Replace all the parts, following the steps described above in the reverse order.
b) Minimum regulation of the main and top gas oven burner with thermostat:
light the burner as described in the paragraph “the oven knob” of the instruction booklet.
turn the knob to Max for about 10 minutes and then turn the knob to the Min setting;
remove the knob;
regulate the screw positioned outside the thermostat pin until the flame is small but steady.
N.B.: in the case of liquid gas, the regulation screw must be screwed in to the bottom.