Cannon C50GCK Cooktop User Manual


 
9
Burner and Nozzle Specifications
Table 1 Liquid Gas Natural Gas
Burner Diameter Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Thermal Power
kW (p.c.s.*)
Nozzle
1/100
Flow*
l/h
(mm) Nominal Reduced (mm) (mm) *** ** Nominal Reduced (mm)
Fast
(Large)(R)
100 94 2,60 0,7 41 80 189 186 2,60 0,7 118 248
Semi Fast
(Medium)(S)
75 69 1,90 0,4 30 70 138 136 1,90 0,4 104 181
Auxiliary
(Small)(A)
51 46 1,00 0,4 30 52 73 71 1,00 0,4 76 95
Main Oven - - 2,60 0,6 36 71 189 186 2,60 0,6 123 248
Grill - - 3,60 2,4 - 94 240 236 3,60 1,3 134 343
Top Oven - - 2,00 0,6 34 66 145 143 2,00 0,6 104 190
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
Coniston
C50GCW
C50GCS
C50GCX
C50GCK
C50GCIS
C50LCIS