Mains Electricity Connection
Incorrect installation may be dangerous and the manufacturer can not be held responsible.
Warning! This appliance must be earthed The manufacturer declines all responsibility for any
problem caused by failure to observe this rule.
THIS APPLIANCE MUST BE CONNECTED TO THE MAINS SUPPLY BY A COMPETENT PERSON,
USING FIXED WIRING VIA A DOUBLE POLE SWITCHED FUSE SPUR OUTLET AND PROTECTED BY A
SUITABLE FUSE (16A MINIMUM).
We recommend that the appliance is connected by a qualified electrician, who is a member of the
N.I.C.E.I.C. and who will comply with the I.E.E. and local regulations.
The wires in the mains lead of this appliance are coloured in accordance with the following code:
Green & Yellow = Earth, Blue = Neutral, Brown = Live.
As the colours of the wires in the mains lead for the appliance
may not correspond with the coloured markings identifying the
terminals connecting to the fuse spur, proceed as follows:
• The wire which is coloured green and yellow must be
connected to the terminal marked E (Earth) or coloured
green.
• The wire which is coloured blue must be connected to the
terminal marked N (Neutral), or coloured black.
• The wire which is coloured brown must be connected to the
terminal marked L (Live), or coloured red.
Note: Use a suitable fuse (16A minimum).
Assembly and electrical connection should be carried out by
specialised personnel.
When installing this product we recommend you seek the help of
another individual.
FUSE ON
FUSE SPUR OUTLET
DOUBLE POLE SWITCHED
Fig. 40
USE A SUITABLE FUSE
(16A MINIMUM)