9
Care and Maintenance
Descaling
If the display shows DESCALING then the coffee machine needs to be descaled to ensure best performance.
Please note:
You should use cleaning products that are appropriate for use with coffee machines.
Do not use lemon-based products to descale the coffee machine as these can cause irreparable damage to the coffee
machine.
Failure to descale your coffee machine constitutes misuse and may invalidate your guarantee.
To descale the coffee machine, follow the steps below:
1. If the coffee machine is plumbed into the mains water supply, turn off the tap.
2. Open the drip tray drawer and remove the drip tray grid.
3. Remove any water from the drip tray and coffee grounds from the container. Then close the drip tray
drawer without replacing the grid.
4. Position the steam nozzle so that any water drips into the drip tray.
5. Switch on the coffee machine and wait until the WATER and STEAM have stopped flashing.
6. Switch off the coffee machine.
7. Press and hold until PROGRAMMING shows on the display.
8. Select the descaling function by pressing or until DESCALING shows on the display.
9. Press and hold and together and then press until the coffee machine beeps.
10. When DESCALING STAGE 01 shows on the display, fill the tank half full with descaling product, then
press .
11. When DESCALING STAGE 02 shows on the display, open the steam nozzle.
12. When DESCALING STAGE 03 shows on the display, the coffee machine will dispense water from both the
coffee dispenser and steam nozzle.
13. When DESCALING STAGE 04 shows on the display, refill the water tank with fresh water, then
press .
14. When DESCALING STAGE 05 shows on the display, the coffee machine will start the cleaning cycle.
15. Turn the control knob to close the steam nozzle.
16. Fill the water tank and wait for the coffee machine to confirm both coffee and water temperatures have
been reached.
Your coffee machine is now descaled and ready for normal use.
IMPORTANT: if the coffee machine is plumbed into the mains water supply, it must be installed with a
mains water isolation valve and 150 micron filter.