CDA HVN61/81 Cooktop User Manual


 
Mains Electricity Connection
Warning! this appliance must be earthed
We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who
will comply with the I.E.E. and local regulations.
This appliance is intended to be connected to fixed wiring and is not suitable for connection to a 13a plug or
13a supply.
This appliance is intended to be connected to fixed wiring by a double pole switch, having a contact separation of at
least 3mm in all poles. The switch must be positioned no further than 2m from the appliance.
This appliance is supplied with a 3 core mains cable; the wires are in accordance with the following code:
Green & Yellow = Earth
Blue = Neutral
Brown = Live
Please note:
The mains cable must only be replaced by a qualified service engineer and must be of equivalent or
better rating (i.e. 2.5mm
2
, HO5V2V2-F).
This appliance is intended to be connected to the mains supply with a cable of cross section area 2.5 mm2. A larger
cable will not fit the terminal connections.
The marking of the current rating of the fuse or circuit breaker protecting this appliance should be marked on the
socket outlet.
Assembly and electrical connection should be carried out by specialised personnel.
When installing this product we recommend you seek the help of another individual.
Fig.7
Black - grey
Green / yellow
Blue
Brown
N
L
Green / yellow
Blue
Brown
N
L
Use a 32A circuit breaker or fuse