CDA HVN 32 Cooktop User Manual


 
7
Thermal Protection
The induction cooktop is fitted with safety devices to protect
the electronic system and each cooking zone from overheating.
Overheating of Cooking Zone
Cooking zone OFF: the cooking zone display shows "
H "
and " C " alternating or just " C " blinking.
Cooking zone ON: the cooking zone display alternates
between set power level and "
C ".
No power is delivered to the cooking zone.
Let the cooking zone cool down before using.
Overheating of Induction Generator
Cooking zone OFF: the cooking zone display shows "
H "
and " " alternating or just " " blinking.
Cooking zone ON: the cooking zone display alternates
between set power level and "
".
No power is delivered to the cooking zone.
Let the cooking zone cool down before using.