Conversion to Natural Gas or to LPG
Injectors Replacement of Top Burners
Every cooker is provided with a set of injectors for the various types of gas.
Injectors not supplied can be obtained from the After-Sales Service.
Select the injectors to be replaced according to the table at page 47.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the body of each injector.
To replace the injectors proceed as follows:
– Remove the pan supports, the burner caps and flame speaders.
– Using a wrench, substitute the nozzle injectors “J” (figs. 44 - 45) with those most suitable for the kind of
gas for which it is to be used (see “Table for the choice of the injectors”).
The burners are constructed in such a way so as not to require the regulation of the primary air.
J
J
Triple Ring
burner
Adjusting of the Minimum of the Top Burners
Considering that in the minimum position the flame must have a length of about 4 mm and must remain lit
even with a quick turn from the maximum position to that of minimum.
The flame adjustment is done in the following way:
– Turn on the burner
– Turn the tap to the MINIMUM position
– Take off the knob
– With a thin screwdriver turn the screw “F“ until adjustment is
correct (fig. 46).
Normally for LPG, tighten up the regulation screw.
Auxiliary,
Semi-Rapid
and Rapid
burners
F
Fig. 44
Fig. 45
Fig. 46