44
Electrical Installation
For your safety please read the following information:
WARNING! Before effecting any intervention on the electrical parts the appliance must be
disconnected from the network.
IMPORTANT: The oven must be installed in accordance with the manufacturer’s instructions.
Incorrect installation, for which the manufacturer accepts no responsibility, may cause
damage to persons, animals and things.
General
– The connection to the electrical network must be carried out by qualified personnel and must be
according to existing norms.
– The appliance must be connected to the electrical network verifying above all that the voltage
corresponds to the value indicated on the specifications plate and that the cables section of the electrical
plant can bear the load which is also indicated on the plate.
– If the appliance is supplied without a power supply plug and if you are not connecting directly to the
mains, a standardized plug suitable for the load must be fitted.
– The colours of the wires in the appliance power cable may not correspond with the colours marked on
the terminals of your electrical plug. The plug should always be wired as follows:
• connect the green/yellow wire to the terminal marked with the letter E or the earth symbol or
coloured green/yellow;
• connect the blue wire to the terminal marked with the letter N or coloured black;
• connect the brown wire to the terminal marked with the letter L or coloured red.
– The bi-polar plug must be connected to an outlet connected to the
grounding unit in conformity to security norms.
– If the oven is to be connected directly to the mains, it must be placed with
an omnipolar switch with minimum opening between the contacts of
3 mm between the appliance and the mains.
– The power supply cable must not touch the hot parts and must be
positioned so that it does not exceed 75°C at any point.
– Once the oven has been installed, the switch or socket must always be
accessible.
– If the power supply cable is damaged it must be substituted by a suitable
cable available in the after sales service.
Note: For connection to the mains, do not use adapters, reducers or
branching devices as they can cause overheating and burning.
If the installation requires alterations to the domestic electrical system call
an expert.
He should also check that the socket cable section is suitable for the power
absorbed by the appliance.
The connection of
the appliance to the
grounding unit is
mandatory.
The manufacturer
declines every
responsability for
any inconvenience
resulting from the
inobservance of this
condition.