Vermont Casting DVBR36 Ventilation Hood User Manual


 
23
DVBR Series Direct Vent Gas Fireplace
20000584
1. Turn off gas.
2. Let the fireplace cool if it has been operating.
3. Remove valve cover. (Fig.47)
4. Release the two (2) clamps at the bottom of the
window frame by pulling back on the clamp handles.
(Fig. 48)
5. Lift off the glass frame as shown. (Fig. 48)
6. To reinstall glass follow the above procedure in re
-
verse.
Glass Information
Only glass approved by CFM Corporation
may be used for replacement.
Glass Frame Removal
Glass Cleaning
Replacement of Ceramic Hearth Panels
1. Remove glass.
2. Remove two (2) hex nuts securing grate to hearth
pan. (Fig. 49)
3. Set left and right panels on hearth and bring towards
front of unit.
4. Replace grate assembly.
It is necessary to clean the glass periodically. During
start-up condensation, which is normal, forms on the
inside of the glass and causes lint, dust and other
airborne particles to cling to the glass surface. Also
initial paint curing may deposit a slight film on the glass.
It is therefore recommended the glass be cleaned
two or three times with a non-ammonia household
cleaner and warm water (gas fireplace glass cleaner
is recommended). After initial use glass should be
cleaned two or three times during heating season.
Clean glass after first two weeks of
operation.
Do not clean glass when hot.
Do not use abrasive cleaners.
Do not strike or slam the glass.
G584-501 
Remove glass frame
2/99 djt
Clamps
Glass Frame
Fireplace
Front
Glass
Panel
Glass
Panel
Pull Clamp
Hook
Fig. 48 Glass panel removal.
G584-501
H100
hearth Panels
3/15/99 djt
Grate
Burner
Hearth Panels
Front of Unit
H100
Fig. 49 Hearth panel location.
Operating Instructions
G584-500
Remove valve cover
2/99 djt
Valve Cover
Valve
Fig. 47 Valve cover location.
G584-500
Pins
Locating Holes
The use of any non-approved replacement glass will
void all product warranties.
Care must be taken to avoid breakage of the glass.
Do not operate appliance with glass front
removed, cracked or broken.
Replacement glass (complete with gasket) is
available through your CFM Corporation dealer
and should only be installed by a licensed
qualified service person.