Vermont Casting IRHEDV32 Ventilation Hood User Manual


 
6
10003929
INSTALLATION OF TRIM SWITCH
FOR RP GAS VALVES
1.
Thread wire through openings on the right side of
fireplace. Do not cut wire or insulation on metal edges.
2. Slide switch assembly from the back, between
subframe and trim, then fasten the screw. (Fig. 3)
3. For left side installation reverse switch position in
bracket and repeat Step 2 (Fig. 4 ).
4. Connect wiring to gas valve (Fig. 5a & b) and switch.
CAUTION: DO NOT WIRE MILLIVOLT
REMOTE WALL SWITCH FOR GAS
FIREPLACE TO A 120V POWER SUPPLY.
ADJUSTMENT OF LEVELLING BAR
(IF REQUIRED)
1. Determine height of adjustment.
2. Loosen the four (4) screws. (Fig. 6)
3. Set bar at proper height and tighten the screws.
4. Add the two (2) extra screws to prevent any movement.
VENTING AND INSTALLATION
1. The Irving Oil fireplace may be installed in and
vented through any solid fuel fireplace that has a
minimum fireplace opening 28-3/4" wide x 21-1/4"
high x 16" deep and has been installed in
accordance with the National, Provincial/State and
local building codes and is constructed of non-
combustible materials.
2. Only HEDVT (8 x 12) or HEDVT (12 x 12)
termination kit and flex vent kit HEDVK25 or
HEDVK35 is able to be used in this installation.
Under no circumstances should B vent or C vent
be used on this application.
3. Any flue damper must be removed or blocked open.
4. The chimney must be clean and in good working
order and constructed of non-combustible materials.
5. Make sure that all chimney cleanouts fit properly so
air cannot leak into the chimney.
6. Install the appliance without trim frame and make all
gas fittings and electrical connections.
7. Install the decorative trim frame. Please refer to the
Frame Assembly instructions.
Fig. 6
Trim
Screw
Wiring from millivolt
gas valve
On/Off switch
assembly
Fig. 3
Bracket Switch
On/Off switch
Trim
Screw
Trim
Left
Side
Trim Top
On/Off Switch
Assembly
Wiring from millivolt
gas valve
Fig. 4
Fig. 5a
Fig. 5b
-----
-----
LEVELLING BAR
SET SCREWS
BACK OF UNIT
P
I
L
O
T
TPTH
TP
TH
SIT VALVE
THERMOPILE
ON/OFF SWITCH OR
MILLVOLT THERMOSTAT
PILOT
ADJ
TH
TP
TP
TH
HONEYWELL VALVE