CAUTION
If ignition does NOT occur in 5 seconds, turn the
control knob CLOSED, wait 5 minutes and repeat the
lighting procedure. If the burner does not ignite with
the valve open, gas will continue to flow out of the
burner and could accidently ignite with risk of injury.
Turn control knob and LP cylinder OFF when not in
use.
WARNING
Lighting Instructions:
• Do not lean over appliance while lighting.
• Read all instructions before lighting.
1. Turn the control knobs clockwise until fully tightened in
CLOSED position
2. Turn on gas cylinder
3. Place lit match next to inner burner.
4. Turn Right control knob counter clockwise until burner
lights.
5. Place lit match next to outer burner.
6. Turn Left control knob counter clockwise until burner
lights.
7. If ignition does not occur in 5 seconds, turn the burner
control knob CLOSED, wait 5 minutes, and repeat lighting
procedure.
If flame is accidently extinguished close all control valves
and then repeat lighting instruction.
Match
Match
Lighting
Hole
Match
Hole
Plate
Swing Plate
to expose
Matchlighting
Hole
Control
Knob
Turning Appliance Off
• Turn control knob clockwise to the CLOSED position. Turn LP
cylinder off by turning hand-wheel clockwise to a full stop.
Hose Check
• Before each use, check to see if hose is cut, worn or kinked.
Replace damaged hose before using applaince. Clean only
with mild soap and water. Use only valve/hose/regulator
specified by manufacturer.
General Appliance Cleaning
• Plastic parts: Wash with warm soapy water and wipe dry.
Do not use citrisol, abrasive cleaners, degreasers or a
concentrated grill cleaner on plastic parts. Damage to and
failure of parts can result.
• Painted surfaces: Wash with mild detergent or non-abrasive
cleaner and warm soapy water. Wipe dry with a soft non-
abrasive cloth.
Normal
Hose
Kinked
Hose
High Flame
Low Flame
High Flame
Page 9
Burner Flame Check
• Light burner. Turn control knob from OPEN to CLOSED. The
Flame height should decrease and then go out. Always check
flame prior to each use. If only low flame is seen refer to
"Sudden drop or low flame" in the Troubleshooting Section.