SEQUENCE OF OPERATIONS
When using these instructions refer to the OES 20.20 wiring schematic.
1 When incoming power (220 VAC) is connected to the combi, 220 VAC is sent to
a The contacts 2,4 and 6 of the Safety Contactor (KO)
b The terminals 2 and 5 of the Control Power Switch (S1)
2 When the Control Power Switch (S1) is turned on (closed)
a The red light on the switch is energized.
b Incoming power (220 VAC) is sent through the 2A fuses (F1.1 and F1.2) to
The 12 vdc power supply (G1)
12vdc is sent to terminals 3 and 4 of the connector X10 on the Control
Board (A10)
Terminal 1 of connector X12 on the Control Board (A10)
Terminal 10 of connector X13 on the Control Board (A10)
The return of the Supply is sent to terminal 7 of connector X13 on the Control
Board (A10)
c With 220 VAC to the Control Board (A10) The Operation Board (A11) is
energized
An alarm will sound for one second
All the LED’s and the display will energize one at a time.
“STARTING” will be displayed for 3 seconds
“please wait” will be displayed
The international model number will be displayed
The time and date will be displayed and this will continue until the on/off
switch is depressed.
3 When the ON/OFF is depressed with the combi in the steam mode with time on the
timer, the door closed and the start switch is depressed
a The front display will include a lighted bar under the steam symbol
When the heat circuit is energized the heat symbol will be energized
The cooking mode symbol will be energized.
The time display will invert and begin to count down.
b The fan circuit is energized
If the combi fan is in the normal setting 220 VAC is sent from terminal 5 on
connector X11 through the normally closed auxiliary contacts of contactor
K57 to the coils of contactor K56 and contactors K55.1 for the upper motor
and K55.2 for the lower motor
The K56 contactor closes sending 220 VAC through the Q56.1 overload to
the motors.
The K55.1 contactor closes completing the high speed circuit to the upper
motor and the upper motor turns at a high speed.
The K55.2 contactor closes completing the high speed circuit to the lower
motor and the lower motor turns at a high speed