COMBI OVEN-STEAMER
Stacking Kits for Gas Table Type Models
(OGB 6.10 on OGB 10.10 or OGS 6.10 on OGS 10.10)
SECT. IIB PAGE 5B
0707
by
by
Cleveland
Cleveland
Model # Description
CSTK-1010 for mounting one 6.10 model on top of one 10.10 model
CSTK-1010CA for mounting one 6.10 model on top of one 10.10 model (with casters)
UNIT A
UNIT B
6.00"
R
C
C
S
W
1
W
2
D
G
4.38"
NOTE: Overall height of unit does not change for units with casters.
U
6.10
on 10.10
GAS
RC
CS
W1 W2
D
G
RC
CS
W1 W2
D
G
4.38"
48.54”
39.21"
NOTE: Overall height of unit does not change for units with casters.
UNIT A
UNIT B
L
EFT SIDE VIEW
U
78.41"
36.70"
1.58"
1
.82"
28.43
5.00"
38.98"
6.00"
80.00”(MIN.HOOD REQUIREMENT)
2.52"
7
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located
next to the unit.
Allow for sufficient clearance on left side for service access (contact the
factor
y ser
vice department for recommendations).
Installation must comply with all local fire and health codes.
Electrical Requirements:
120 volt, 60 Hz, single phase,
UNIT A -
11.7 amps
Do not connect to a G.F.I. outlet.
UNIT B -
11.7 amps
Gas Connection: 3/4" NPT
Gas T
ype:
Natural Gas (Propane optional)
Gas Flow Pressure:
Natural Gas - Min. 5.5" WC / Max. 14" WC
Propane Gas - Min. 11" WC / Max. 14" WC
BOILER MODELS UNIT A - OGB-6.10 UNIT B - OGB-10.10
T
otal Connected Load:
45.400 BTU
75,700 BTU
Steam Generator:
45.400 BTU
68,200 BTU
Hot Air: 45.400 BTU 75,700 BTU
BOILERLESS MODELS UNIT A - OGS-6.10 UNIT B - OGS-10.10
T
otal Connected Load:
45.400 BTU
75,700 BTU
Hot Air:
45.400 BTU 75,700 BTU
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
Water Connections: Cold Water (drinking water quality)
Flow Pressure:
30 - 60 PSI
W
ater Inlets: 3/4" GHT-F (Female Garden Hose Connection)
T
reated W
ater for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
V
enting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details, see spec sheet for each
individual combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
W1
W2
D
RC
S
CS
AV
G
E1
E2