COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.10 on OEB 10.10 or OES 6.10 on OES 10.10)
SECT. IIB PAGE 5F
0707
by
by
Cleveland
Cleveland
™
Model # Description
CSTK-1010 for mounting one 6.10 model on top of one 10.10 model
CSTK-1010CA for mounting one 6.10 model on top of one 10.10 model (with casters)
UNIT A
UNIT B
6.00"
R
C
C
S
W
1
W
2
D
4
.38"
NOTE: Overall height of unit does not change for units with casters.
U
RC
CS
W1 W2
D
RC
CS
W
1
W
2
D
3
7.83"
NOTE: Overall height of unit does not change for units with casters.
LEFT SIDE VIEW
U
NIT A
UNIT B
4.38"
48.54"
6
6.10
on 10.10
ELEC
3
78.41"
36.70"
1.58"
1.82"
28.43
5.00"
38.98"
6.00"
80.00”(MIN.HOOD REQUIREMENT)
2.52"
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to
the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
ser
vice department for recommendations).
•
Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F.I. outlet.
BOILER UNIT A - OEB-6.10 UNIT B - OEB-10.10
MODELS
208/3/60
240/3/60
440/3/60
480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
T
otal Connected Load:
9.9 KW
12.8 KW 11 KW 13.1 KW 16.4 KW 21.6 KW 18.5 KW 22 KW
Hot Air: 8.6 KW
11.4 KW 9.1 KW 10.2 KW 14.7 KW 19.6 KW 16.5 KW 19.6 KW
Steam Generator: 7.7 KW
10.2 KW 8.6 KW 10.2 KW 12.8 KW 17.1 KW 14.3 KW 17.1 KW
Amps per Phase: 27.3 30.8 15.2 16.3 45.5 51.8 24.2 26.4
BOILERLESS
UNIT A
- OES-6.10 UNIT B - OES-10.10
MODELS
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
T
otal Connected Load:
9.9 KW
12.8 KW
11 KW
13.1 KW
6.4 KW
21.6 KW 18.5 KW 22 KW
Hot Air: 8.6 KW
11.4 KW
9.1 KW
10.2 KW
14.7 KW
19.6 KW 16.5 KW 19.6 KW
Amps per Phase: 27.3
30.8
15.2
16.3
45.5
51.8 24.2 26.4
W1
W2
D
RC
S
CS
AV
G
E1
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 30 - 60 PSI
W
ater Inlets:
3/4" GHT
-F (Female Garden Hose
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
V
enting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details,
see spec sheet for each individual
combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
W1
W2
D
RC
S
CS
AV
G