Cleveland
™
P
roject ________________________________
I
tem __________________________________
Quantity _______________________________
FCSI Section ____________________________
A
pproval _______________________________
D
ate __________________________________
1333 East 179 St.,
Cleveland, Ohio, U.S.A. 44110
Tel: 1-216-481-4900
Fax: 1-216-481-3782
Web Site: www.ClevelandRange.com
Email: Steam@ClevelandRange.com
COMBI OVEN-STEAMER
Stacking Kits for Electric Table Type Models
(OEB 6.10 on OEB 6.10 or OES 6.10 on OES 6.10)
SECT. IIB PAGE 5E
0707
by
by
Cleveland
Cleveland
™
Model # Description
CSTK-610 for mounting two 6.10 models
C
STK-610CA for mounting two 6.10 models (with casters)
6
.00"
78
RC
CS
W1 W2
D
4.38"
39.50"
4
NOTE: Overall height of unit does not change for units with casters.
U
37.83"
LEFT SIDE VIEW
36.70"
1.58"
1
.82"
2.52"
RC
CS
W1 W2
D
RC
CS
W1 W2
D
NOTE: Overall height of unit does not change for units with casters.
4.38"
3
8.08"
28.43
5.00"
67.8 5 "
28.43
6.00"
78.00”(MIN.HOOD REQUIREMENT)
U
NIT A
UNIT B
U
NIT A
UNIT B
R
6.10
on 6.10
ELEC
6
UTILITIES (Utility connection shown below are listed per unit)
Required Clearances:
Rear - 2", Left Side - 4", Right Side - 2 1/2"
• Allow for sufficient distance if a "high heat source" (i.e. Broiler) is located next to
the unit.
• Allow for sufficient clearance on left side for service access (contact the factory
service department for recommendations).
• Installation must comply with all local fire and health codes.
Electrical Requirements:
Do not connect to a G.F
.I. outlet.
BOILER UNIT A - OEB-6.10 UNIT B - OEB-6.10
MODELS
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load:
9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW
Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW
Steam Generator: 7.7 KW 10.2 KW 8.6 KW 10.2 KW 7.7 KW 10.2 KW 8.6 KW 10.2 KW
Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
BOILERLESS
UNIT A
- OES-6.10 UNIT B - OES-6.10
MODELS
208/3/60 240/3/60 440/3/60 480/3/60 208/3/60 240/3/60 440/3/60 480/3/60
Total Connected Load:
9.9 KW 12.8 KW 11 KW 13.1 KW 9.9 KW 12.8 KW 11 KW 13.1 KW
Hot Air: 8.6 KW 11.4 KW 9.1 KW 10.2 KW 8.6 KW 11.4 KW 9.1 KW 10.2 KW
Amps per Phase: 27.3 30.8 15.2 16.3 27.3 30.8 15.2 16.3
W1
W2
D
RC
S
CS
AV
G
E1
Water Connections: Cold Water (drinking water quality)
Flow Pressure: 30 - 60 PSI
W
ater Inlets:
3/4" GHT
-F (Female Garden Hose
Connection)
Treated Water for Steam Generator
Untreated Water for Condenser
Drain Connection: 2" Tube
V
enting:
Exhaust Hood required
*Connection for Cleaning Solution
*Connection for Rinse Cycle
*
Available as an option
Note: For additional connection details,
see spec sheet for each individual
combi model to be stacked.
W1
W2
D
RC
S
CS
AV
G
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
G
E1
E2
W1
W2
D
RC
S
CS
AV
W1
W2
D
RC
S
CS
AV
G