2.2.3. Connecting the Scrap Accumulator and Drain
The scrap accumulator is designed to perform two basic functions:
1. It allows all the heavy solids to discharge out of the machine with each wash cycle and
collect in a clean out tray.
2. It provides accumulation capacity to allow draining the contents of one cycle regardless
of the discharge rate of the existing drain.
The drain pipe is connected to the scrap accumulator drain using a 2” no-hub connector (not
supplied) as shown in
Figure 2.2.3 below.
Figure
2.2.3
2.2.4. Installer’s Checklist
Dishmachine checked for concealed damage
Hot water supply is minimum 120°F, recommended 140° F (49/60 C)
Incoming water supply line is ¾” minimum (not galvanized)
Supply circuit breaker for machine is properly sized
Service voltage and phase type are correct to machine data plate
Drain pipe is installed with adequate air gap (must meet local codes)
Dishmachine is properly grounded
Dishmachine is properly leveled
Machine circuit breaker is labeled “DISHWASHER”
Machine has been connected with correctly sized wire