2. Remove the plug from the mixing chamber located by the vacuum breaker on the
back of machine; and install the rinse injection fitting (supplied with your
dispenser).
3. A 7/8” detergent injection hole is provided in the back of the wash tank. Remove
the S.S. plug and install the detergent fitting (supplied with your dispenser).
4. A 7/8” chemical probe hole is provided in the front of the wash tank heater just
below hi limit switch. Insert the probe into the hole from inside the wash tank and
secure it with the probe retaining nut provided. Connect ring connectors to the
probe with nuts and star washers provided.
5. The final step of installing the CMA supplied Detergent and Rinse Dispenser is
programming it to your specific application. The reference manual supplied with
the dispenser shows you how to program it.
Keep in mind while reading the reference manual that the CMA-180 operates
in “probe” mode. (This mode is selected by setting a value of “1” in screen
21).
Screen 22 must be set to “1” (Door).
There are four user functions with this dispenser. Their operation is described in the
reference manual.
MODEL CMA-180 INSTALLATION & OPERATION Rev. 2.04 Page
7