Creda CRC95 Ventilation Hood User Manual


 
Installing your Cooker Hood
7
RECIRCULATION:
The chimney hood is supplied specified for
installation in the extraction mode. To convert
to recirculation it will be necessary to obtain
the optional carbon filter.
In the recirculation mode,contaminated air
enters the chimney hood and passes through
the grease filter and carbon filter and then out
into the kitchen through two grilles,at either
side of the chimney.
To convert the chimney hood to recirculation
proceed as follows:
1. Remove the metal grease filter,push the
securing tabs towards the centre and pull
the filter downwards (Fig.7).
2. Fit the carbon filter and secure to the hood
with two screws provided (Fig.8).
3. Push the metal grease filter back into
place.
4. Fit the recirculation spigot (Fig.6 15F) to
the ducting pipe as illustrated on the
installation instructions.
NOTE: The two venting grilles must not be
fitted into the chimney stack until the
chimney stack has been installed onto the
wall above the canopy.
EXTRACTION:
Ducting Fitting
The chimney hood can be ducted to the out-
side,using either rigid or flexible ducting of
150mm. The choice of ducting is left to the
discretion of the installer,however,the best
performance will be obtained by using
150mm of rigid ducting. Where flexible duct-
ing is fitted it should not be turned through
very tight bends as this could impair the per-
formance of the hood.
The ducting must be manufactured from fire
retardant material conforming to the relevant
British Standard or DIN 4102-B1.