Dacor DR30DH Range User Manual


 
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide
Dual Fuel Range
Document # PG05-006
Revised 01/30/13 Page 3/6
Note 3
Note 6
E
F
3
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of
cabinet front, see Product Dimensions.
4
Consult local code for exact location requirements.
6
Model DR30D[H]: 37 7/8 (96.2 cm) max.
Model DR30DI[H]: 37 7/16 (95.1 cm) max.
2
Distance to combustible surfaces measured from cooking
surface (top of cooktop grate); if installing an overhead
range hood, also check the hood specifications for minimum
required clearances.
1
Minimum distance to a combustible rear wall for model
DR30DI[H] is 2.5” (6.4 cm) from top rear trim. Model DR30D[H]
may be ins
talled flush to rear wall, but non-combusible surface
or 9-inch backguard (PNADB3009) is recommended.
Back wall
1
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
2
13
” (33.0 cm)
max.
5
18” (45.7 cm)
min.
2, 5
Suggested
location of
utilities
4
5
This specification does not apply for cabinets located
greater than a horizontal distance of 10” (25.4 cm)
from the edge of the range.
Cutout Dimensions
E F***
36” (91.4 cm)*
30” (76.2 cm)**
30
1
/
16
” (91.6 cm)
* Recommended ** Minimum
*** See following page for model DR30DI[H]
Gas and Electrical Service
The shaded area shown below denotes the location of the gas inlet
and the electrical junction box/receptacle. This is the recommended
location. For replacement purposes, the location of the existing
utilities may be utilized provided they do not interfere with the sides
or rear of the range. Check local building codes for permissible gas
valve locations.
An external manual shut-off valve must be installed between the gas
inlet and the range for the purpose of turning on or shutting off gas to
the appliance.
The installation must allow for the following:
Access to the gas shut-off valve when the unit is installed.
Access to the remote circuit breaker panel/fuse box when the range
is in place.
The gas supply piping, gas shut-off valve and the electrical junction
box or receptacle must be located so they do not interfere with the
range when it is installed.
The junction box and gas shut off valve must be located so that
the range can be pulled out for service while the appliance remains
connected.
Cabinet Layout
Carefully check the location where the range is to be installed. For
best performance, the range should be placed away from drafts that
may be caused by doors, windows and heating and air conditioning
outlets.
To reduce the risk of personal injury and to reduce accumulated
smoke in the room, Dacor strongly recommends installing a range
hood or raised vent (model DR30DI[H] only). A range hood should
project horizontally a minimum of five (5) inches beyond the face of
the cabinets.
All maximum and minimum dimensions and clearances shown in the
diagram below must be maintained for safe operation.
Any openings in the wall behind the appliance or in the floor
underneath it must be sealed.
Carefully note the requirements stated below for clearances to walls
and cabinets.
REQUIRED CABINET
DIMENSIONS
Cabinet tolerances: -1/16”, (+1.6 mm) -0