Dacor DR30DH Range User Manual


 
All specications subject to change without notice.
Phone: (800) 793-0093www.dacor.com
PLANNING
GUIDE
DR30D, DR30DH, DR30DI, DR30DIH
Distinctive 30” Wide
Dual Fuel Range
Document # PG05-006
Revised 01/30/13 Page 6/6
Cabinet tolerances: -1/16”, (+1.6 mm) -0
MODEL DR30DI[H]/ERV3015 COUNTERTOP
AND CABINET FRONT SELF-RIMMED,
3 1/4 INCH SIDE PANELS REMOVED
Cabinet face
Range side
panel removed
Countertop
Range trim resting
on countertop
Back of control
panel and trim
behind door
rest against
cabinet face
DR30DI[H] range
3/8” min. (1.0 cm)
flat countertop
overhang required
behind cutout
ERV3015
raised vent
3/8” min. (1.0 cm) space
required behind ERV3015
chassis to clear stiffener
H
rear wall recommended
Non-combustible
countertop and
cabinet opening
29 1/4” (74 3 cm)
27 1/2” (69.9 cm)
2 9/16”
(6.5 cm)
10” min.
(25.4 cm)
both sides
Countertop height: min: 35 7/16” (90.0 cm) max: 37 7/16” (95.1 cm)
Notch countertop to
3/8” min. (1.0 cm)
countertop
overhang
raised vent opening
H
Combustible side
wall above range
below countertop
Cabinet face
To countertop
front
K
30” (76.2 cm)
TOP VIEW
SIDE VIEW
Model DR30DI[H]
Range and ERV3015
Raised Vent With
H J K
Countertop and
Cabinet Front
Self-Rimmed (side
panels removed)
23 7/8” *
(60.6 cm)
NA
0” (0 cm) to
2 1/8” (5.4 cm)
* Cabinet face below countertop must be flush with back of notch in
countertop
Countertop height for all self-rimming installations:
35 7/16” (90.0 cm) minimum, 37 7/16” (95.1 cm) maximum
Self-Rimming Installation With Raised Vent
(Option 3)
Only model DR30DI[H] may be installed with a raised vent. Use only
Dacor raised vent model ERV3015.
A self-rimming countertop configuration is required for raised vent
installation. On installations with a raised vent, when sliding the range
into position, it will stop when the rear of the control panel or side
panels contact the notches toward the front of the countertop.
The self-rimming installation of the DR30DI[H] range and ERV3015
raised vent create a “built-in” look where the range trim overlaps the
countertop on both sides and the raised vent overlaps the countertop
in back. It is also possible, if the cabinets are deep enough, to self
rim the front of the range into the cabinet face immediately behind the
control panel and door trim or behind the side panels (see side views
on bottom right and previous page). The rear range trim will partially
cover the front of the raised vent chassis in back.