Dacor EO Oven User Manual


 
10
Installation Instructions
Before proceeding, turn off power to the circuit to which 1.
the oven will be connected at the circuit breaker or fuse
box.
Position the oven directly in front of the cabinet cutout.
2.
Feed the appliance conduit into the electrical junction 3.
box and attach it using a UL approved strain relief.
Depending upon local codes, utilize one of three meth-
4.
ods to connect the appliance to the electrical power:
Connect to a four wire electrical system◊
Connect to a three wire electrical system, where ◊
local codes permit
Connect to a three wire electrical system with ◊
external ground, according to local codes.
Connecting to a Four Wire Electrical
System
Separate the wires coming out of the appliance conduit.1.
Connect the white wire from the appliance conduit to 2.
the white (neutral) supply wire in the junction box.
Connect the black wire from the appliance conduit to 3.
the black (L1) supply wire in the junction box.
Connect the red wire from the appliance conduit to the
4.
red (L2) supply wire in the junction box.
Connect the green wire from the appliance conduit to 5.
the green (ground) wire in the junction box.
Electrical Service Installation
WARNING
Wire the oven only in compliance with local ordi-•
nances.
If the electrical service provided does not meet •
the product specifications, do not proceed with the
installation. Call a licensed electrician to install the
required wiring.
To prevent an electric shock or fire hazard, turn off •
power to the circuit at the circuit breaker or fuse box
prior to connecting the wiring to the oven.
Improper connection of the electrical wiring can •
cause an electric shock hazard and damage the
appliance. Dacor is not responsible for damages
resulting from improper installation.
Connect the ground terminal (or lead) on the appli-•
ance to a grounded, metallic, permanent wiring sys-
tem or grounding conductor.
Do not use an extension cord with this appliance. •
Such use may result in fire, electric shock or other
personal injury.
Do not install a fuse in the neutral or ground circuit. •
A fuse in the neutral or ground circuit may result in
an electric shock hazard.
The appliance must be connected to the power sup-•
ply with copper wire only. The use of aluminum wire
may result in unsatisfactory connections.
Flexible armored or non-metallic, sheathed copper •
cable (with grounding wire) should be used to con-
nect the appliance to the junction box. An UL-listed
connector must be used to directly connect the cable
to the junction box.
IMPORTANT
Make sure that the conduit is long enough to allow the
oven to be pulled out for service without disconnecting it
from power.
Conduit from
appliance
Cable from
power supply
Wire nut
(4 places)
Junction
box
RED
RED
GREEN
GREEN
WHITE
WHITE
BLACK
BLACK
4 Wire Junction Box Connection