F14 AND 48000 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
10
F14 AND 48000 Series Service and Installation Manual
11
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
WIRING DIAGRAMS: F14EI AND 48300 SERIES
L1 G
HEATER 1
L2
CONTROL
PILOT LIGHT
"INFINITE"
HEATER 2
PILOT LIGHT
HEATER 3
PILOT LIGHT
HEATER 4
PILOT LIGHT
HEATER 5
PILOT LIGHT
HEATER 6
PILOT LIGHT
120 or 208-240V
SINGLE PHASE MODELS
L1 G L3
208-240V 3 PHASE MODELS
HEATER 1
L2
CONTROL
PILOT LIGHT
"INFINITE"
HEATER 4
PILOT LIGHT
HEATER 2
PILOT LIGHT
HEATER 5
PILOT LIGHT
HEATER 6
PILOT LIGHT
CONTROL
"INFINITE"
HEATER 3
PILOT LIGHT
1000 W - 120V
or 1000/1222 W -
208/230 V
heating element
pilot light (furnished)
infinite control
with “OFF” position
to additional
food warmers
line wires
P
L1
L2
H1
H2
(NEUTRAL ON 120V MODELS)