F14 AND 48000 Series Service and Installation Manual
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
10
F14 AND 48000 Series Service and Installation Manual
11
For customer service, call (800) 733-8829, (800) 773-8821, Fax (989) 773-3210, www.deleld.com
Single Phase
WIRING DIAGRAMS: F14EW SERIES
Three Phase
120-208 OR 120-240 VOLT SINGLE PHASE SUPPLY
WHITE-NEUTRAL
L2-BLACK L1-RED GREEN-GROUND TO CASE
SWITCH
BLACK
WATER LEVEL
CONTROL BOARD
C2
POWER RELAY
120VAC COIL
PILOT LIGHT
219-4095
BLACK
RED
BLACK
IMMERSION
HEATER
HEAT
FILL
H
N
XL HI C
FLOAT
BLUE
TEMPERATURE
CONTROL
LOW WATER LIGHT
WATER FILL
SOLENOID
WHITE
THERMAL
OVERLOAD
ON HEATER
RED
120-208 OR 120-240 VOLT THREE PHASE SUPPLY
WHITE-NEUTRAL
L2-BLACK
L1-RED
GREEN-GROUND TO CASE
SWITCH
RED
WATER LEVEL
CONTROL BOARD
C3
POWER RELAY
120VAC COIL
PILOT LIGHT
219-4095
L3-BLUE
RED
WHITE
THREE PHASE
IMMERSION
HEATER
HEAT
FILL
H
N
XL HI C
FLOAT
BLUE
TEMPERATURE
CONTROL
LOW WATER LIGHT
WATER FILL
SOLENOID
WHITE
THERMAL
OVERLOAD
ON HEATER
RED
L3-BLUE
BLACK
L1-RED
L2-BLACK
OPTIONAL
OPTIONAL