Electrical Connection
A standard unit is provided with a power cord and grounded
plug.
The unit should be plugged into a receptacle with its own circuit
protection that matches the amperage of the plug.
Connections must be made in accordance
with all applicable local codes and/or the
National Electrical Code. Refer to the
amperage data on pages 3-4 and the wiring
diagrams on pages 9-12 to be sure the unit
is connected to the proper power source. A
protected circuit of the correct voltage and
amperage must be run for connection of the
line cord.
On cord-connected units, the ON/OFF switch
must be turned to its OFF position and
power supply disconnected whenever doing
the following:
1. Performing maintenance functions.
2. Cleaning the refrigerated cabinet area.
3. Performing service or repair functions.
Under no circumstances should a refrigerated unit be operated
without the louvered panel in place.
Installation
Location
Units represented in this manual are for indoor use only. Be
sure the location chosen has a floor strong enough to support
the total weight of the cabinet and contents. A fully loaded
model may weigh as much as 3000 pounds! Reinforce the floor
as necessary to provide for maximum loading.
For the most efficient refrigeration, be sure to provide good air
circulation inside and out. Be sure that the exterior of the unit
has access to ample air. Avoid hot corners and locations near
stoves and ovens. It is suggested the rear of the unit be no
less than two inches from any wall, partition or any other object
which will restrict exhaust air flow.
Unit requires that the sides and bottom are not
any closer than 3” to any combustible material.
Leveling
A level cabinet looks better and will perform more efficiently
when the doors line up with the door frames properly, the
cabinet will not be subject to undue strain and the corners of the
shelves will not move around on the supports. A level heated
unit will maintain an equal water depth when water is used in
the wells. Use a level to make sure the unit is level from front to
back and side to side.
Stabilizing
All models are supplied on casters for your convenience, ease
of cleaning underneath and for mobility.
The unit must be installed in a stable
condition with the front wheels locked,
locking the front casters after installation is
the owner’s responsibility.
Plumbing
Refrigerated units have a drain that exits the unit on the bottom
and is located on the operator’s left side. Standard units on
casters or legs will have a bronze gate valve that fits a standard
garden hose. Drain connections are on the operator side below
the pan in the open shelf area.
Moisture collecting from improper drainage
can create a slippery surface on the floor
and a hazard to employees. It is the owner’s
responsibility to provide a container or
outlet for drainage.