Shelleybasic by Delfield Service & Installation Manual
7
For customer service, call (800) 733-8829, (800) 733-8821, Fax (989) 773-3210, www.delfield.com
Delfield
™
®
Operation SE-F And SES-F
Frost tops are designed to maintain an even layer of frost to
pleasantly display desserts and pies. Once turned on, the
compressor will run continuously. The unit should be turned off
overnight or when not in use.
Since it takes time for frost to accumulate initially, the unit
should be turned on approximately an hour before it is actually
required. Product should not be placed on the frost top prior to
turning the unit on, because it may freeze to the surface of the
unit.
Operation SE-HC And SES-HC
The hot and cold combination pans must be operated with
water in the well.
Hot Operation
Fill well with a minimum of 4” of water. Place function switch
in HOT position. Turn thermostat dial to highest position and
allow unit to warm up. Then reset the thermostat to maintain
the desired temperature.
Never use anything more than plain water in the
wells or tank. Failure to observe this warning
may result in personal injury or damage to the
unit.
When operated at the highest temperature
setting, the top of the unit will become very
hot. Staff and customers using the equipment
should be informed about this.
To turn unit off, simply move the function switch to OFF
position. Drain water and allow unit to cool before cleaning or
switching to cold operation.
Cold Operation
Simply place the function switch to the COLD position. The
compressor controller has been factory set and no temperature
adjustment should be necessary. When the cold pan is used
with ice, use perforated bottoms. These will allow ice to melt
properly.
Switching from Hot to Cold Operation
Follow the following procedure:
1) Place the function switch in the OFF position
and drain off hot water.
2) Allow the unit to cool until it can be safely
cleaned.
3) When clean up procedures are complete,
unit will be ready for cold operation.
To assure maximum compressor life, do not
switch from “hot” to “cold” operation without
allowing a cool down period. Never switch from
hot to cold operation while hot water remains in
the pans. Failure to observe this warning will
greatly reduce compressor life and eventually
cause premature compressor failure.
Switching from Cold to Hot Operation
No special procedure is required to switch from cold to hot
operation. Be sure to fill with a minimum of 4” of water.
This unit is designed so that the compressor
and the heating elements cannot operate at
the same time. Continued operation of the
compressor in the “hot position” should not
be considered normal. Call for service if this
happens.
The unit must be turned off when not in use or overnight for
defrosting and cleaning.
Reversing And Replacing Panels
Shelleybasic laminated panels are reversible. All panels are
replaceable. The panels sit in an upper and lower track.
Remove first an end panel. Gain access from the back of the
unit. Place one hand inside the unit on the panel, and one hand
on the panel outside the unit. Push the panel out and lift the
panel up. Remove the panel from the lower track and then the
upper track. By removing an end panel first you will have better
access to the front panel. Repeat the process for the front panel
and the other end panel.
To install new or reversed panels, insert the panel into the
upper track. Continue placing the panel into the unit and lower it
into the lower track.