DeLonghi DEFSGG 36 Oven User Manual


 
21
SETTING THE BURNER MINIMUM
When switching from one type of gas to another, the minimum flow rate must also be
correct: the flame should not go out even when passing suddenly from maximum to
minimum flame.
To regulate the flame follow the instructions below:
Semirapid and triple ring burners
Light the burner
Set the gas valve to position
Remove the knob
With a thin screwdriver pass by the hole of microswitch and turn the screw F until
adjustment is correct (fig. 2.7).
Inside crown of DUAL burner
Light the DUAL burner
Set the gas valve to position
Remove the knob
Using a screwdriver turn the screw H until the correct setting is obtained (fig. 2.8).
Outside crowns of DUAL burner
Light the DUAL burner
Set the gas valve to position
Remove the knob
Using a screwdriver turn the screw G until the correct setting is obtained (fig. 2.8).
For LP/PROPANE gas, tighten the adjustment screws completely.
Fig. 2.7
Fig. 2.8
F
G
H