1. Make sure that the electric service supply voltage is AC 120V,
60Hz.
2. Follow all local electrical and safety codes, as well as the
National Electrical Code (NEC) and the Occupational Safety
and Health Act (OSH Act).
3. Always disconnect the power source before working on or
near the ventilating fan, motor or junction box.
4. Protect the power cord from sharp edges, oil, grease, hot
surfaces, chemicals or other objects.
5. Do not kink the power cord.
6. Do not install the unit where ducts are
congured as shown in
Fig. A.
7. Provide suction parts with proper ventilation.
8. This unit is UL listed for use over a bathtub or shower when
installed in a GFCI (Ground Fault Circuit Interrupter) protected
branch circuit.
9. These ventilating fans are intended for residential usage only.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufactu
rer.
2. Before servicing or cleaning the unit, switch the power o at
the service panel and lock the service disconnecting means to
prevent the power from being switched on accidentally. When
the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the
service panel.
3. Installation work and electrical wiring must be done by
qualied person(s) in accordance with all applicable codes
and standards, including re-rated c
onstruction.
4. Sucient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning
equipment to prevent back drafting. Follow the heating
equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE) and
local code authorities.
5. When cutting or drilling into a wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducte
d ventilating fans must always be vented to the
outdoors.
7. If this unit is to be installed over a tub or shower, it must be
marked as appropriate for the application and be connected
to a GFCI – protected branch circuit.
8. Do not use this unit with any other solid-state control device.
Solid-state controls may cause harmonic distortion, which can
cause a motor humming noise.
9. NEVER place a switch where it can be reached from a tub or
shower.
10. Not to be installed in a ceiling thermally insulated to a value
gre
ater than R40. (This is required for installation in Canada
only).
11. Do not open/disassemble the LED light engine.
Turning angle too large Duct shrink
ydob eht raen woblEswoble ynam ooT
Body
Fig. A
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. Not for use in cooking areas. (Fig. B)
3. This product must properly connect to the grounding
conductor of the supply circuit.
4. To reduce the risk of injury to persons, install the fan at least
8.2 feet (2.5 m) above the oor.
45
°
Cooking area
45
°
Do not install above or
inside this area
Cooking
Equipment
floor
Fig. B
Page 1.
MODEL SIG110LED
INSTALLATION AND OPERATING INSTRUCTIONS
VENTILATION FAN/LED LIGHT/ LED NIGHT-LIGHT
READ AND SAVE THESE INSTRUCTIONS
GENERAL SAFETY INFORMATION