Delta Electronics SIG110D Ventilation Hood User Manual


 
Page 4.
MODELS SIG80 / SIG80M / SIG110 / SIG110D / SIG110H
Motion Model: SIG80M
Factory setting: low speed airow 40CFM, time delay 15 minutes.
Humidity Model: SIG110H
DIMENSION
5-2. Motion control mode: Turn the POWER switch on to operate at
motion control mode. When motion is detected, the fan will run at
full speed and the LED indicator will be amber. When motion is
not detected, the fan will continue to run at the full speed until
the user -adjustable time delay has elapsed, and then will
automatically change to the user-adjustable low speed airow.
The LED indicator will be green.
5-3. Humidity control mode: Turn the POWER switch on to operate
at humidity control mode - the LED indicator will be blue. When
the ambient humidity is higher than the user -adjustable set-point,
the fan will run at full speed. When the ambient humidity is lower
than the set-point, the fan will continue to run at the full speed
until a 10-minute time delay has elapsed, and then will auto
matically change to the user-adjustable low speed airow.
5-4. Full speed mode: Turn the MODE switch on to operate at full
speed mode - the LED indicator will be amber.
5-5. Humidity tolerance is about ±10%. Long -time operation will
inuence the detecting precision as dust accumulates. The
humidity switch may need to be adjusted.
Factory setting: low speed airow 60CFM, humidity 60%RH
MAINTENANCE WARNING:
Disconnect the power source before working on the unit. Routine
maintenance must be done every year.
CAUTION:
1. Never use gasoline, benzene, thinner or any other such chemi-
cals to clean the ventilating fan.
2. Do not allow water to enter the mot or
3. Do not soak resin parts in water over 60°C (140°F)
CLEANING
1. Pull down the springs to remove the grille.
2. Wash and clean the grille. (Use non -abrasive kitchen detergent
and wipe dry with a new cloth.)
3. Remove dust and dirt from the ventilating fan
4. Using a cloth dampened with non -abrasive kitchen detergent,
remove any dirt from ventilating fan. Wipe dry with a new cloth
5. Replace the grille
WARRANTY
DELTA ELECTRONICS THREE YEAR LIMITED WARRANTY
Delta Electronics Inc. (“Delta Electronics”) warrants to the
original consumer purchaser in the USA that the Breez
ventilation fan products will be free from defects in material or
workmanship. This warranty is limited to three (3) years from
the original date of purchase.
Limitations and Exclusions
1. During the warranty period, a replacement for any defective
product will be supplied free of charge for installation by the
consumer. The warranty provided herein does not cover
charges for labor or other costs incurred in the troubleshooting,
repair, removal, and installation service.
2. All returns of defective parts or products must include the
product model number, and must be made through an
authorized Delta Electronics distributor. Authorized returns
must be shipped prepaid. Repaired or replacement products
will be shipped by Delta Electronics
F.O.B. shipping point.
3. Delta Electronics shall not be liable for any indirect, inciden-
tal, consequential, punitive, or special damages arising out of or
in connection with products use or performance, regardless of
the form of action whether in contract, tort (including
negligence), strict product liability or otherwise.
4. This warranty does not extend to uorescent lamp starters
and tubes.
5. The warranty does not cover if user does not comply with
manufacturer’s installation manual.
6. To qualify for warranty service, you must notify Delta
Electronics at the address or telephone number below.
7. Delta Electronics shall have no liability to the original
owner-user with respect to any defect caused by abuse, misuse,
neglect, improper transportation or storage, improper testing,
improper installation, improper operation, improper use,
improper maintenance, improper repair, improper alteration,
improper modifcation, tampering or accident of products or
parts thereof, or unusual deterioration or degradation of
products or parts thereof due to a physical environment
beyond the requirements of products’ specifcations.
Address: 4405 Cushing Parkway, Fremont, CA 94538
US Toll Free Number: 1-888-979-9889
SPECIFICATIONS
Model No.
Voltage
(V)
Frequency
(Hz)
Power
@ 0.1”SP
(W)
Air Flow
@ 0.1”SP
(CFM)
Weight
(lb.)
Power
(W)
Note
SIG80 120 60 8.2 80 10 18.0 Single Speed
SIG80M 120 60 8.2 80 10 18.0 Motion Sensor
SIG110 120 60 12.7 110 10 23.0 Single Speed
SIG110H 120 60 12.7 110 10 23.0
Humidity
Sensor
SIG110D 120 60 12.7 110 10 23.0 Dual Speed
Note: Design and specications subject to change without notice.