GAS EQUIPMENT ASSEMBLY
SOI FNOID VALVE
BURNER MOUNTING
FIG. 12
BVRNER
/SPARK
ELECTRODE
Shown
in open position
PRESSURE TEST PORT
1
2
The correct operating pressure is 11 inches of water
column. The correct place to take the LP gas pres-
sure is at the test port just ahead of the burner jet.
(See FIG. 12).
Inspect the flue baffle. It should be reasonably clean
and free of soot. Heavy soot formation indicates im-
proper functioning of the burner. The flue and burner
both require cleaning in the following manner:
Unplug the refrigerator power cord from the 120 volt
AC outlet. (See FIG. 3).
Disconnect or shut off the 12 volt power to the refrig-
erator.
Turn manual shutoff valve to OFF. (See FIG. 1).
Removecoverfrom
the burner housing. (See FIG. 1).
Disconnect the wire from the high voltage electrode.
Remove the burner mounting screws and remove the
burner assembly. (See FIG. 12).
Remove the wire and the flue baffle from the top of
flue tube. Clean the flue from the top using a flue
brush. Blowing compressed air into the flue will not
properly clean soot and scale out of the flue tube.
Replace the flue baffle.
Clean burner tube with a brush. Blow out burner with
compressed air.
Before removing burner jet, clean burner area of soot
and scale that fell out of flue tube. Remove the burner
jet. Soak the jet in wood alcohol and blow it out with
compressed air. Re-install and tighten burner jet.
NOTE: The color of the flame shall be clear blue
over the slots of the burner. (See FIG. 13).
Clear blue color
of flame
L
FIG. 13
00 NOT use a wire or pin when cleaning the burner
jet as damage can occur to the precision opening.
This can cause damage to the refrigerator or create
a fire hazard.
10. Reinstall burner, being careful that the end of the
burner fits into the slot on the burner bracket. Check
to make sure slots are centered under the flue tube
and the thermocouple is positioned properly (tip of
thermocouple extends over
ho
slots of burner).
11.
Be sure to reconnect the wire to high voltage elec-
trode. Check the electrode for proper location and
gap. (See FIG. 14).
FIG. 14
Electrode
Burner tube
12.
Turn on manual gas shutoff valve and check all fit-
tings for leaks.
13. Connect 120 volt power cord to the outlet and re-
connect
or
turn on the 12 volt DC power.
14. Check LP gas safety shutoff. See page 6.