Wall unit mounting - Fig. 6
Only for extractor version: position the upper section of the
chimney so that the oulet slots H are not visible (see also A-B-C
sequence on on Fig. 6).
Fix each other both parts of the hood (1), make all connections
between the two parts (2) and fix with 6 screws (3).
Mark the wall with a centre line, this will aid mounting (4), position
the template so that the mid line printed on the template matches
with the center line previously drawn, the lower side of the template
corresponds to the lower side of the hood once mounted (5).
Drill two holes Ø 8mm and fix the support bracket with two wall plugs
and screws (6). Hang the hood (7) and adjust its position (8-9).
From the inside of the hood mark two points for final fixing (10).
Remove the hood (11) and drill two holes Ø 8mm (12), fit two wall
plugs (13).
Rest the chimney support bracket G against the wall, touching the
ceiling. Use the support bracket as a drilling template and mark 2
holes with a pencil (14), dril the holes insert 2 wall plugs, fix the
chimney support bracket to the wall using two screws (15) (If the
hood is to be used in filter version, fix deflector F to the chimney
support bracket G using 4 screws).
Hang the hood again (16) and fix it with two screws (17).
Connect an exhaust pipe to the outlet hole of the hood B (18) for
direct discharge of fumes to the outside (Extractor version) or to be
connected to the connection ring located on the bottom of the
deflector F (Filter version).
Make the electrical connections (19).
Fit the chimney sections and fix them at the top to the chimney
support G (20b) using 2 screws (20a), slide the bottom section of
the chimney down until it completely covers the suction unit and
slots into the housing provided on top of the hood (21) and fix with 2
screws.