Electrolux 3531 WK-M Range User Manual


 
16
For Universal LPG the regulator is
fitted to the gas inlet of the
appliance so that a pressure test
point is available. The regulator
should be disabled by adjusting the
regulator adjusting screw to be fully
screwed in, but do not remove the
locking nut from the regulator. The
supply pressure to the appliance is
controlled by the regulator located
on the LPG cylinder. This cylinder
regulator should be adjusted to give
a pressure of 2.75kPa at the
appliance inlet with the large and
simmer burners operating at
maximum.
Use of Hose Assemblies.
If the appliance is to be installed
using a hose assembly, then
1. The hose must be AGA certified
to AS/NZS 1869 as class B or
class D, and utilised in
accordance with requirements of
AS 5601 (AG 601).
2. The connection point between the
consumer piping and the hose
must be accessible with the
appliance installed.
Adjusted for LPG
Typical Adjustment
for Natural Gas
B2004
9
The wok-unit has a special pan support
which enables use of a wok pot with
curved bottom.
When using cooking utensils with a
flat bottom the diameter of the utensils
must not be less than 26 cm.