8
Installation
Your freezer needs air
For correct operation this appliance must be located in a dry atmos-
phere, away from heat sources, e.g. cookers, radiators, boilers and
direct sunlight.
You should also ensure that air can circulate freely around the back
and the top of the cabinet. There should be 100mm (4”) between the
top of the cabinet and any overhanging kitchen furniture.
Alternatively allow 50mm (2”) between the top of the cabinet and any
overhanging kitchen furniture and a gap of 25mm (1”) on either side
of the appliance.
If your appliance is installed under a
continuous worktop, an air outlet
opening of at least 200 cm
2
and a
ventilation grille (A/B) matching the
worktop design should be installed at
the rear of the worktop.
The cut surfaces of the worktop (C)
should be varnished to avoid swelling
due to penetration of moisture.
The appliance wall distance must be
at least 30 mm and should be
checked before the ventilation grille is inserted.
Special accessories:
A Ventilation grille, brown
B Ventilation grille, white
AEG36
A/B
200 cm
2
105
C
570
550
93-103