and safety instructions must be adhered to. Considering the numerous
installation conditions which are possible, there is no way of providing
detailed information here.
It is necessary to avoid overheating of the refrigerator by maintaining
adequate distances from heat sources and by the use of a suitable
thermal insulation plate. Proper ventilation of the appliance must also
be ensured.
8
Installation
Your Freezer Needs Air
Integratable models (i-appliances)
The integrated door of the furniture cabi-
net largely seals the installation recess.
i-appliances must therefore be provided
with ventilation by having an opening in
the furniture plinth. The warmed air must
be able to be exhausted upwards through
the air shaft on the furniture back. The
ventilation cross-sections should be at least
200 cm
2
.
Warning - To ensure the appliance functions correctly, never cover or
obstruct the ventilation openings.
min. 200 cm
2
i 200
2
50
Building-in
Please check whether, after installing your appliance and especially
after reversing the door, the door seal seals right round. A badly fitting
door seal may lead to heavy frosting and thereby to a higher power
consumption (see also „What to do if...“).
Dimensions of the recess
Height of housing 880 mm
Depth of housing 550 mm
Width of housing 560 mm
It is necessary that the cabinet
has a ventilation recess (at least
200 cm
2
)
.