16
Operation
VERIFYING THE OPERATION
Before beginning the test procedure, ensure that the gas supply is turned off at the
shut-off valve, all cooktop control valves are in the “OFF” position, and all burner
rings, burner caps, and grates are properly positioned on the cooktop.
Rotate one knob at a time counterclockwise to the “HI/LITE” position. Verify that all
ignitors spark continuously, then return the knob to the “OFF” position. Repeat for
!
WARNINGWARNING
WARNINGWARNING
WARNING
• If the cooktop fails to operate properly, ensure that the electrical power supply
and gas supply are turned on and that all installation steps have been carefully
followed. Call a qualified service technician if the cooktop still does not operate
properly.
• The cooktop and shut-off valve must be disconnected from the gas supply piping
during any pressure testing exceeding 1/2 pound per square inch (3.5 kPA).
• The cooktop must be isolated from the gas supply piping by closing the shut-off
valve during any pressure testing at or below 1/2 pound per square inch (3.5 kPA).
Figure 8
all knobs. See Figure 8.