Electrolux EFC70011 Ventilation Hood User Manual


 
22 electrolux INSTALLING THE COOKER HOOD
EN
Extraction (Ducted)
The cooker hood is more effective when
installed in the extraction mode (ducted
to the outside).
Venting kits may be purchased through
your retailer or DIY store, and must be
evacuated through an outside vent of
ø125 (5ins) or ø150mm (6ins).
The ducting used must be manufactured
from re retardent material conforming
to the relevant British Standard or DIN
4102-B1.
When the cooker hood is ducted to
the outside the charcoal lter must be
removed.
Fitting the Ducting
• Fit the ø150mm (6ins) ducting to the
spigot on top of the hood body as
illustrated.
• When using ø125mm (5ins) ducting t
item 9 and 10 on to the spigot on the
top of the hood body as illustrated.
For the best performance use the
shortest possible run of ducting and
we recommend the use of rigid pipe in
preference to exible hose as this will
improve the ow of air while reducing
turbulence, which causes noise and a
loss of performance.
• If the room where the cooker hood
is to be used contains a fuel burning
appliance such as a central heating
boiler, then its ue must be be of the
room sealed or balanced ue type.
• If other types of ue or appliances are
tted ensure that there is an adequate
supply of air to the room.
The cooker ducting when tted in
the extraction mode must never be
connected to central heating ues,
radiators or water heaters.
9
ø 125
10
ø 150