Electrolux EFC70011 Ventilation Hood User Manual


 
INSTALLING THE COOKER HOOD electrolux 23
EN
15
Recirculation Mode
The cooker hood is supplied speci ed for
use in the recirculation mode, with the
charcoal lter tted.
In the recirculation mode contaminated air
is passed through the charcoal lter to be
puri ed and recirculated into the kitchen
through the grille outlets on either side of
the chimney.
• Push t the air outlet connector item
15 onto the air outlet.
Ensure the activated charcoal lter
has been tted.
Fitting the Upper Chimney
• Slightly widen the two sides of the
upper chimney and hook them behind
the brackets item 7.2.1 ensuring they
are correctly seated.
• Secure the sides to the brackets using
the 4 screws item 12c (2.9 x 9.5mm)
supplied.
Fitting the Lower Chimney
• Slightly widen the two sides of the
lower chimney and hook them
between the upper chimney and
the wall, ensuring they are correctly
seated.
• Fix the lower chimney to the hood
body using 2 screws item 12c (2.9 x
9.5mm) supplied.
Make sure that the air outlet
connection is aligned with the
chimney outlets.
12c
12c
12c
2.2
2.1
2