Description of the Appliance
The cooker hood is supplied ready for use as a
recirculation hood and may be used for
extraction by removing the charcoal filter
which has been fitted inside the cooker hood.
Extractor version
In this version fumes are extracted to the
outside via a hose connected to the coupling
ring. Fig. 1.
Attention: The hose is not supplied and must
be purchased separately.
Remove the charcoal filter:
EFI 635
Open the extraction grille: move the two sliders
towards the centre (in the OPEN direction)
and release the grille downwards. Fig. 2a.
EFI 640
Remove the grease filters: first pull the handles
upwards, then extract the filter outwards. Fig.
2b.
Turn the charcoal filter anti-clockwise to
release it from its housing and remove it. Fig. 3.
Attention!
EFI 635: one charcoal filter
EFI 640: two charcoal filters
To refit the extraction grille (EFI 635): it
should be inserted above between the
appropriate guides until it latches into place,
and after having attached the grille to the
cooker hood also in the lower part move the
two sliders outwards (in the CLOSED
direction). Fig. 2a.
To refit the grease filter (EFI 640): they
should be inserted above between the
appropriate guides until it latches into place,
and after having attached the grille to the
cooker hood also in the lower part. Fig. 2b.
In order to obtain the best performance the hose
should have a diameter equal to the outlet hole.
Fig. 1
Coupling ring
Hose
Fig. 2a - EFI 635
Fig. 2b - EFI 640
Guides
Fig. 3
Charcoal Filter
OPEN
CLOSED
OPEN
CLOSED
Guides
To the outside