Location
The hob may be located in a kitchen, a
kitchen/diner or bed sitting room, but
not in a bathroom, shower room or
garage.
Ensure that there is a minimum distance
of 55 mm between the rear cut out edge
and the wall.
A minimum distance of 450 mm must
be left between the side edges of the
cut out and any adjacent cabinets or
walls.
The minimum distance combustible
material can be fitted above the hob in
line with the edges of the hob is 400
mm. If it is fitted below 400 mm a space
of 50 mm must be allowed from the
edges of the hob.
The minimum distance combustible
material or a cooker hood can be fitted
above the hob is 650 mm.
For appliances installed in the Republic
of Ireland please refer to NSAI-
Domestic Gas Installation I.S 813
Current Edition Section 7- Permitted
Locations of Appliance.
It is important to install the elbow correctly, with the shoulder on the
end of the thread, fitted to the hob connecting pipe.
Failure to ensure the correct assembly will cause leakage of gas.
Gas Connection
Connection to the gas supply should be with either rigid or semi-rigid pipe, i.e. steel
or copper.
The connection should be suitable for connecting to R 1/2 (1/2 BSP male thread).
When the final connection has been made, it is essential that a thorough leak test is
carried out on the hob and installation.
Ensure that the main connection pipe does not exert any strain on the hob.
600