Electrolux EOG 600 Oven User Manual


 
2. CONNECTION TO ELECTRICITY SUPPLY
WARNING: This appliance must be earthed, do not earth this appliance to the gas supply piping.
This appliance must be connected to a 220V-240V a.c. 50Hz supply which incorporates a 3 ampere fuse. If
any other type of plug is used it should incorporate a 5 ampere fuse in either the plug or adapter or at the
distribution board. The appliance is supplied with 2 meters (6.5 ft) of 5 ampere 3 core cable, fitted with a
moulded plug. If this proves insufficient to allow the appliance to be plugged into the nearest supply socket,
the supply cable can be either:-
i) Replaced totally by a longer cable at least 0.75mm² nominal cross sectional area (24/0.2).
ii) Extended by using a B.E.A.B. approved 3-way sealed flex connector with integral flex clamps.
DO NOT EXTEND THE CABLE USING PLASTIC OR
CERAMIC CONNECTION TERMINAL BLOCKS AND/OR
INSULATION TAPE.
If the supply cable is replaced it is recommended that the
ends of the new cable all be cut to the same length 60mm,
any excess wire being stored inside the mains terminal see
Fig.5.
Should the supplied cable be required to be threaded
through small apertures in the cabinets it can be removed
from the mains inlet terminal block see Fig.5.
If the supplied plug is cut off dispose of it safely as it will be
a shock hazard if inserted into a 13 amp socket elsewhere
in the house.
To fit a 3 pin 13 amp plug to the end of the appliance cable
(Fig.6). Connect the wires as follows:
BROWN to the live terminal.
BLUE to the neutral terminal.
GREEN and YELLOW to the earth terminal.
As the colours of the wires in the mains lead of this appliance
may not correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
The wire which is GREEN and YELLOW must be connected to
the terminal in the plug which is marked with the letter 'E' or by
the earth symbol or coloured GREEN or GREEN and
YELLOW.
The wire which is coloured BLUE must be connected to the
terminal which is marked with the letter 'N' or coloured black.
The wire which is coloured BROWN must be connected to the
terminal which is marked with the letter 'L' or coloured RED.
FIT A 3 AMP FUSE TO THE PLUG FUSE HOLDER
39
FIG.5
FIG.6