Electrolux EOG 900 Range User Manual


 
4 Turn off the electricity supply and the thermostat; disconnect the pressure gauge and replace the test
point plug . Turn on gas supply and check for gas soundness.
NOTE: The electrical supply must be connected in order to test the pressure.
4. RE-ASSEMBLE THE APPLIANCE
1 Re-fit the fascia panel. (See section A below).
2 Re-fit the oven door.
(See section B on page 43).
A. REMOVAL OF FASCIA PANEL
1 Remove the gas control knobs and timer control knobs.
2 Remove the four screws (two each side) which are visible on the underside of the fascia. Fig.8.
3 Tilt the bottom of the fascia panel out over. Withdraw the fascia panel by moving it down over to
disengage it from the top fixing lugs.
4 Replace in reverse order.
NOTE: To prevent the top fascia panel mounts becoming slack, it may be necessary to adjust the top fixing
lugs.
42
PRESSURE TEST
POINT
INLET ELBOW
FIG.7
FIG.8